Chapter Noninvasive Acquisition of the Aortic Blood Pressure Waveform (Record no. 38159)

MARC details
000 -LEADER
fixed length control field 03007naaaa2200313uu 4500
001 - CONTROL NUMBER
control field https://directory.doabooks.org/handle/20.500.12854/70628
020 ## - INTERNATIONAL STANDARD BOOK NUMBER
International Standard Book Number intechopen.86065
024 7# - OTHER STANDARD IDENTIFIER
Standard number or code 10.5772/intechopen.86065
Terms of availability doi
041 0# - LANGUAGE CODE
Language code of text/sound track or separate title English
042 ## - AUTHENTICATION CODE
Authentication code dc
072 #7 - SUBJECT CATEGORY CODE
Subject category code TB
Source bicssc
100 1# - MAIN ENTRY--PERSONAL NAME
Personal name Priidel, Eiko
Relationship auth
245 10 - TITLE STATEMENT
Title Chapter Noninvasive Acquisition of the Aortic Blood Pressure Waveform
260 ## - PUBLICATION, DISTRIBUTION, ETC.
Name of publisher, distributor, etc. InTechOpen
Date of publication, distribution, etc. 2019
506 0# - RESTRICTIONS ON ACCESS NOTE
Terms governing access Open Access
Source of term star
Standardized terminology for access restriction Unrestricted online access
520 ## - SUMMARY, ETC.
Summary, etc. Blood pressure reflects the status of our cardiovascular system. For the measurement of blood pressure, we typically use brachial devices on the upper arm, and much less often, the radial devices with pressure sensors on the wrist. Medical doctors know that this is an unfortunate case. The brachial pressure and even more, the radial pressure, both are poor replacements for the central aortic pressure (CAP). Moreover, the devices on the market cannot provide continuous measurements 24 h. In addition, most of the ambulatory and wearable monitors do not enable acquisition of the blood pressure curves in time. These circumstances limit the accuracy of diagnosing. The aim of this chapter is to introduce our experiments, experiences and results in developing the wearable monitor for central aortic blood pressure curve by using electrical bioimpedance sensing and measurement. First, electronic circuitry with embedded data acquisition and signal processing approaches is given. Second, finding appropriate materials, configurations and placements of electrodes is of interest. Third, the results of modelling and simulations are discussed for obtaining the best sensitivity and stability of the measurement procedures. Finally, the discussion on the provided provisional experiments evaluates the obtained results. The conclusions are drawn together with the need for further development.
540 ## - TERMS GOVERNING USE AND REPRODUCTION NOTE
Terms governing use and reproduction Creative Commons
Use and reproduction rights https://creativecommons.org/licenses/by/3.0/
Source of term cc
-- https://creativecommons.org/licenses/by/3.0/
546 ## - LANGUAGE NOTE
Language note English
650 #7 - SUBJECT ADDED ENTRY--TOPICAL TERM
Topical term or geographic name entry element Technology: general issues
Source of heading or term bicssc
653 ## - INDEX TERM--UNCONTROLLED
Uncontrolled term blood pressure waveform, central aortic pressure, cardiovascular system, medical indications, diagnosing, electrical impedance, bioimpedance-based sensing, modelling, simulation, signal processing, transfer function, noninvasive measurements, electrodes, wearable devices
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Annus, Paul
Relationship auth
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Kõiv, Hip
Relationship auth
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Pesti, Ksenija
Relationship auth
700 1# - ADDED ENTRY--PERSONAL NAME
Personal name Min, Mart
Relationship auth
773 10 - HOST ITEM ENTRY
Host Biblionumber OAPEN Library ID: ONIX_20210602_10.5772/intechopen.86065_414
Control subfield nnaa
856 40 - ELECTRONIC LOCATION AND ACCESS
Host name www.oapen.org
Uniform Resource Identifier <a href="https://library.oapen.org/bitstream/20.500.12657/49300/1/67018.pdf">https://library.oapen.org/bitstream/20.500.12657/49300/1/67018.pdf</a>
Access status 0
Public note DOAB: download the publication
856 40 - ELECTRONIC LOCATION AND ACCESS
Host name www.oapen.org
Uniform Resource Identifier <a href="https://library.oapen.org/bitstream/20.500.12657/49300/1/67018.pdf">https://library.oapen.org/bitstream/20.500.12657/49300/1/67018.pdf</a>
Access status 0
Public note DOAB: download the publication
856 40 - ELECTRONIC LOCATION AND ACCESS
Host name www.oapen.org
Uniform Resource Identifier <a href="https://directory.doabooks.org/handle/20.500.12854/70628">https://directory.doabooks.org/handle/20.500.12854/70628</a>
Access status 0
Public note DOAB: description of the publication

No items available.