245 1 0 _aChapter Noninvasive Acquisition of the Aortic Blood Pressure Waveform
260 _bInTechOpen
_c2019
506 0 _aOpen Access
_2star
_fUnrestricted online access
520 _aBlood pressure reflects the status of our cardiovascular system. For the measurement of blood pressure, we typically use brachial devices on the upper arm, and much less often, the radial devices with pressure sensors on the wrist. Medical doctors know that this is an unfortunate case. The brachial pressure and even more, the radial pressure, both are poor replacements for the central aortic pressure (CAP). Moreover, the devices on the market cannot provide continuous measurements 24 h. In addition, most of the ambulatory and wearable monitors do not enable acquisition of the blood pressure curves in time. These circumstances limit the accuracy of diagnosing. The aim of this chapter is to introduce our experiments, experiences and results in developing the wearable monitor for central aortic blood pressure curve by using electrical bioimpedance sensing and measurement. First, electronic circuitry with embedded data acquisition and signal processing approaches is given. Second, finding appropriate materials, configurations and placements of electrodes is of interest. Third, the results of modelling and simulations are discussed for obtaining the best sensitivity and stability of the measurement procedures. Finally, the discussion on the provided provisional experiments evaluates the obtained results. The conclusions are drawn together with the need for further development.
540 _aCreative Commons
_fhttps://creativecommons.org/licenses/by/3.0/
_2cc
_4https://creativecommons.org/licenses/by/3.0/
546 _aEnglish
650 7 _aTechnology: general issues
_2bicssc
653 _ablood pressure waveform, central aortic pressure, cardiovascular system, medical indications, diagnosing, electrical impedance, bioimpedance-based sensing, modelling, simulation, signal processing, transfer function, noninvasive measurements, electrodes, wearable devices
773 1 0 _0OAPEN Library ID: ONIX_20210602_10.5772/intechopen.86065_414
_7nnaa
856 4 0 _awww.oapen.org
_uhttps://library.oapen.org/bitstream/20.500.12657/49300/1/67018.pdf
_70
_zDOAB: download the publication
856 4 0 _awww.oapen.org
_uhttps://library.oapen.org/bitstream/20.500.12657/49300/1/67018.pdf
_70
_zDOAB: download the publication
856 4 0 _awww.oapen.org
_uhttps://directory.doabooks.org/handle/20.500.12854/70628
_70
_zDOAB: description of the publication
999 _c38159
_d38159